Version:
Side panel for support leg of folded sheet steel, with perforated panel perforations 9 x 9 mm in a 37 mm grid, to accept GARANT easyFix hooks and holders, as well as perforated panel accessories.
Of sheet metal
modular design. All power components include
cables and
plugs. The modules and covers can be changed / positioned as desired.
•Cable slots are provided on the upper, lower, and end faces for power supplies and for linking multiple media tracks together.
Electrical pre-installation with industrial plug-in system (applies only to media tracks):1 pc. distribution block No.
928492 with 5-pin feed/supply cable and 5 pcs. 3-pin sockets,
1 pc. 5-pin plug connector No.
928490 size 5 included for the feed cable.
Description:
Technical data for industrial plug-in system (No. 928490; 928491; 928492):- Maximum connection value 230 V / AC, 16 A or 400 V / AC, 16 A.
- Total load capacity at AC: 3.5 kW.
- Maximum connected load, three-phase AC: 10.5 kW.
- Conductor cross-section of the pre-assembled cables:
3 × 1.5 mm2 for single-phase AC (L, N, PE)
5 × 1.5 mm2 for three-phase AC (L1, L2, L3, N, PE) - Protection class 1
- Index of Protection IP 20.
Suitable for:
Workbenches height 850 mm, support legs height 800 mm and 650 mm.
Fitted with:
250 V socket No.
928470 size. DE250V/1: 2
No. of empty modules (1U / 2U / 3U): 1× / 0× / 0×
Colour:
RAL 7035 light grey powder coated.
Note:
See No.
928470 for other suitable media modules. The modules No.
928470 of sizes _CEE400/5, _AIR/S, _STOP, _ON/OFF1, _ON/OFF2 and _RCD cannot be incorporated in the side cladding.
Initial connections and also the connection of plugs or sockets to cables should only be performed by a qualified electrician.
Warning:
Intended use- 250 V type F sockets for supplying electronic consumers.
- Mount only on suitable holes.
Reasonably foreseeable misuse- Cannot be combined with modules No. 928470 size CEE400/5, AIR/S, STOP, ON/OFF1, ON/OFF2, RCD.
- Do not operate outdoors or in rooms with high atmospheric humidity.
- Do not use in explosion hazard areas.
- Not for use where there is exposure to intense heat, direct sunlight, naked flames or liquids.